BMP Calculations

Sheet visibility: visible.

Back to workbook

Stored values and formulas are shown below. Cached formula results are source snapshots and have not been recalculated.

Cell Stored value or cached result Formula
A1 Project Name
B1
C1 Description
D1
E1
F1 Analysis Date
G1
H1 BMP or LID Type
I1
J1
K1
L1
M1
N1
O1
P1
Q1
R1
S1
T1
U1
V1
W1
X1
Y1
Z1
AA1 0 =+C14-G14
A2 Sample Project =+'Annual Recharge'!K1
B2
C2 This is a test application =+'Annual Recharge'!K2
D2
E2
F2 37865 =+'Annual Recharge'!K3
G2
H2
I2
J2
K2
L2
M2
N2
O2
P2
Q2
R2
S2
T2
U2
V2
W2
X2
Y2
Z2
AA2
A3 Recharge BMP Input Parameters
B3
C3
D3
E3 Root Zone Water capacity Calculated Parameters
F3
G3
H3
I3 Recharge Design Parameters
J3
K3
L3
M3
N3
O3
P3
Q3
R3
S3
T3
U3
V3
W3
X3
Y3
Z3
AA3
A4 Parameter
B4 Symbol
C4 Value
D4 Unit
E4 Parameter
F4 Symbol
G4 Value
H4 Unit
I4 Parameter
J4 Symbol
K4 Value
L4 Unit
M4
N4
O4
P4
Q4
R4
S4
T4
U4
V4
W4
X4
Y4
Z4
AA4
A5 BMP Area
B5 ABMP
C5 6656
D5 sq.ft
E5 Empty Portion
of RWC under Post-D Natural Recharge
F5 ERWC
G5 0.9264395961538462 =+IF(SegBMP=0,ERWC,(1-0.5C_factor)'BMP Calculations'!C16)
H5 in
I5 Inches of Runoff
to capture
J5 Qdesign
K5 0.5397002023064793 =+VLOOKUP(MATCH(MAX('event calc table'!$G$3:$G$81),'event calc table'!$G$3:$G$81,0),'event calc table'!$A$2:$D$81,4)
L5 in
M5
N5
O5
P5
Q5
R5
S5
T5
U5
V5
W5
X5
Y5
Z5
AA5
A6 BMP Effective Depth,
this is the design variable
B6 dBMP
C6 5.179003184432713
D6 in
E6 ERWC Modified to
consider dEXC
F6 EDRWC
G6 0.9264395961538462 =+IF(SegBMP=0,EDRWC,(1-0.5C_factor)'BMP Calculations'!C17)
H6 in
I6 Inches of Rainfall
to capture
J6 Pdesign
K6 0.672028306791204 =+VLOOKUP(MATCH(MAX('event calc table'!$G$3:$G$81),'event calc table'!$G$3:$G$81,0),'event calc table'!$A$2:$C$81,3)
L6 in
M6
N6
O6
P6
Q6
R6
S6
T6
U6
V6
W6
X6
Y6
Z6
AA6
A7 Upper level of the BMP
surface (negative if above ground)
B7 dBMPu
C7 -5.2
D7 in
E7 Empty Portion
of RWC under Infilt. BMP
F7 RERWC
G7 0.7350024335462353 =+('event calc table'!$A$81/365)'event calc table'!F83+((365-'event calc table'!$A$81)/365)G6
H7 in
I7 Recharge Provided
Avg. over Imp. Area
J7
K7 18.996236666666668 =+'event calc table'!H84
L7 in
M7
N7
O7
P7
Q7
R7
S7
T7
U7
V7
W7
X7
Y7
Z7
AA7
A8 Depth of lower surface of BMP, must be>=dBMPu
B8 dEXC
C8 0
D8 in
E8
F8
G8
H8
I8 Runoff Captured
Avg. over imp. Area
J8
K8 24.774702750770814 =+K7/G15
L8 in
M8
N8
O8
P8
Q8
R8
S8
T8
U8
V8
W8
X8
Y8
Z8
AA8
A9 Post-development Land Segment Location of BMP ,
Input Zero if Location is distributed or undetermined
B9 SegBMP
C9 0
D9 unitless
E9
F9
G9
H9
I9
J9
K9
L9
M9
N9
O9
P9
Q9
R9
S9
T9
U9
V9
W9
X9
Y9
Z9
AA9
A10
B10
C10
D10
E10 BMP Calculated Size Parameters
F10
G10
H10
I10 CALCULATION CHECK MESSAGES
J10
K10
L10
M10
N10
O10
P10
Q10
R10
S10
T10
U10
V10
W10
X10
Y10
Z10
AA10
A11
B11
C11
D11
E11 ABMP/Aimp
F11 Aratio
G11 0.10186715641261096 =+ABMP/$C$15
H11 unitless
I11 Volume Balance->
J11 OK =IF(ABS(G14-C14)<0.001,"OK","Solve Problem to satisfy Annual Recharge")
K11
L11
M11
N11
O11
P11
Q11
R11
S11
T11
U11
V11
W11
X11
Y11
Z11
AA11
A12
B12
C12
D12
E12 BMP Volume
F12 VBMP
G12 2872.620432965345 =+ABMP*(dBMP/12)
H12 cu.ft
I12 dBMP Check--->
J12 OK =IF(dBMP<=dEXC-dBMPu,"OK", "dBMP must be<=dEXC-dBMPu, adjust parameters")
K12
L12
M12
N12
O12
P12
Q12
R12
S12
T12
U12
V12
W12
X12
Y12
Z12
AA12
A13 Parameters from Annual Recharge Worksheet
B13
C13
D13
E13 System Performance Calculated Parameters
F13
G13
H13
I13 dEXC Check--->
J13 OK =IF(dEXC>dBMPu,"OK","make dEXC larger than dBMPu")
K13
L13
M13
N13
O13
P13
Q13
R13
S13
T13
U13
V13
W13
X13
Y13
Z13
AA13
A14 Post-D Deficit Recharge
(or desired recharge volume)
B14 Vdef
C14 103434.50864999997 =+Vdef
D14 cu.ft
E14 Annual BMP Recharge
Volume
F14
G14 103434.50865000003 =+('event calc table'!G84/12)*ABMP
H14 cu.ft
I14 BMP Location--->
J14 Location is selected as distributed or undetermined =IF(SegBMP=0,"Location is selected as distributed or undetermined",IF(VLOOKUP(SegBMP,'Annual Recharge'!H6:I20,2)=0,"Land Segment Number Selected for BMP is not Defined", "OK"))
K14
L14
M14
N14
O14
P14
Q14
R14
S14
T14
U14
V14
W14
X14
Y14
Z14
AA14
A15 Post-D Impervious Area
(or target Impervious Area)
B15 Aimp
C15 65340 =+Aimp
D15 sq.ft
E15 Avg BMP Recharge
Efficiency
F15
G15 0.7667594181760925 =+'event calc table'!G84/'event calc table'!E84
H15 Represents
% Infiltration
Recharged
I15 OTHER NOTES
J15
K15
L15
M15
N15
O15
P15
Q15
R15
S15
T15
U15
V15
W15
X15
Y15
Z15
AA15
A16 Root Zone Water Capacity
B16 RWC
C16 3.9422961538461543 =+IF(SegBMP=0,RWC,VLOOKUP(SegBMP,'Annual Recharge'!AA6:AL20,12))
D16 in
E16 %Rainfall
became Runoff
F16
G16 0.7828979082660678 =+'event calc table'!D84/Pavg
H16 %
I16 Pdesign is accurate only after BMP dimensions are updated to make rech volume= deficit volume. The portion
J16
K16
L16
M16
N16
O16
P16
Q16
R16
S16
T16
U16
V16
W16
X16
Y16
Z16
AA16
A17 RWC Modified to
consider dEXC
B17 DRWC
C17 3.9422961538461543 =+IF(SegBMP=0,DRWC,VLOOKUP(SegBMP,'Annual Recharge'!AA6:AO20,15))
D17 in
E17 %Runoff
Infiltrated
F17
G17 0.6620265749276713 =+'event calc table'!E84*Aratio/'event calc table'!D84
H17 %
I17 of BMP infiltration prior to filling and the area occupied by BMP are ignored in these calculations. Results are
J17
K17
L17
M17
N17
O17
P17
Q17
R17
S17
T17
U17
V17
W17
X17
Y17
Z17
AA17
A18 Climatic Factor
B18 C-factor
C18 1.53 =+C_factor
D18 no units
E18 %Runoff
Recharged
F18
G18 0.5076151114086526 =+G14/(('event calc table'!D84/12)*Aimp)
H18 %
I18 sensetive to dBMP, make sure dBMP selected is small enough for BMP to empty in less than 3 days. For land
J18
K18
L18
M18
N18
O18
P18
Q18
R18
S18
T18
U18
V18
W18
X18
Y18
Z18
AA18
A19 Average Annual P
B19 Pavg
C19 47.8 =+Pavg
D19 in
E19 %Rainfall
Recharged
F19
G19 0.39741080892608105 =+G14/((Pavg/12)*Aimp)
H19 %
I19 Segment Location of BMP if you select "impervious areas" RWC will be minimal but not zero as determined by
J19
K19
L19
M19
N19
O19
P19
Q19
R19
S19
T19
U19
V19
W19
X19
Y19
Z19
AA19
A20 Recharge Requirement
over Imp. Area
B20 dr
C20 18.99623666666666 =12*C14/Aimp
D20 in
E20
F20
G20
H20
I20 the soil type and a shallow root zone for this Land Cover allowing consideration of lateral flow and other losses.
J20
K20
L20
M20
N20
O20
P20
Q20
R20
S20
T20
U20
V20
W20
X20
Y20
Z20
AA20
A21 How to solve for different recharge volumes: By default the spreadsheet assigns the values of total deficit recharge volume "Vdef" and total proposed impervious area "Aimp" from the "Annual Recharge" sheet to "Vdef" and "Aimp" on this page. This allows solution for a single BMP to handle the entire recharge requirement assuming the runoff from entire impervious area is available to the BMP.
To solve for a smaller BMP or a LID-IMP to recharge only part of the recharge requirement, set Vdef to your target value and Aimp to impervious area directly connected to your infiltration facility and then solve for ABMP or dBMP. To go back to the default configuration clik the "Default Vdef & Aimp" button.
B21
C21
D21
E21
F21
G21
H21
I21
J21
K21
L21
M21
N21
O21
P21
Q21
R21
S21
T21
U21
V21
W21
X21
Y21
Z21
AA21
A22
B22
C22
D22
E22
F22
G22
H22
I22
J22
K22
L22
M22
N22
O22
P22
Q22
R22
S22
T22
U22
V22
W22
X22
Y22
Z22
AA22
A23
B23
C23
D23
E23
F23
G23
H23
I23
J23
K23
L23
M23
N23
O23
P23
Q23
R23
S23
T23
U23
V23
W23
X23
Y23
Z23
AA23